Description
The T14-1 Rail transport hearing loop driver offers:
- Compliance to relevant rail standards EN50155, EN50121-3, EN45545
- Cover a whole carriage with a single amplifier
- Unrivalled intelligibility
Service broadcasts and emergency announcements through rail and tram Public Address (PA) systems are now part of everyday life. Their direct connection to the user’s hearing aid means that Hearing Loops are the only assistive listening technology suitable for use on public passenger vehicles. The T14-1 Rail transport hearing loop driver from Ampetronic offers performance you can rely on:
- Generating less heat than other drivers in its class
- Remote technical support and network features to control and configure the system
- Enables reporting features to be integrated with the TCMS
- Metal Loss Correction
- Low lifetime cost
- Excellent reliability backed by a 5 year warranty
The T14-1 replaces the XA88 and is also available for bus and coach transport (see T14-1 Bus transport hearing loop driver) The T14-1 hearing loop driver range has been designed as high quality digital, networkable single loop output drivers. The range includes models intended for use in rail or bus applications. Depending on a number of factors regarding the installation of the loop and the set-up of the driver, the T14-1 range can provide compliance with IEC 60118-4 for appropriately specified loop installations. Compliance to relevant Standards, reduced weight and heat generation have been major factors in the design, combined with optimised performance and the freedom from R.F.I. generation. The T14-1 range has a Class D output stage which offers better than 60% increase in energy efficiency over previous solutions. The products feature WAGO or Harting connectors and use remote control and monitoring via a browser based control panel using standard network protocols; including HTTP, Telnet, email and SNMP. All units feature high power outputs plus ample voltage headroom, making them suitable for any rail, tram or bus application. Networked T14-1 models also feature dual-slope metal loss compensation that caters for a wide range of metal loss frequency characteristics.
Features
- Class D output stage driver for maximum efficiency, unsurpassed in its field
- Less weight than most alternatives in its class
- Options to allow analogue and VOIP audio inputs
- Transformer isolated inputs
- Industrial Ethernet port
- USB firmware update port
Variants
- T14-1LW: 24V power, Wago connectors
- T14-1LH: 24V power, Harting connectors
- T14-1UW: 72-110V power, Wago connectors
- T14-1UH: 72-110V power, Harting connectors
- The T14-1 is compliant with EN 50155 and associated standards including EN 50121-3-2 (EMC) and EN 61373 (shock and vibration). In addition, the T14-1 is compliant with EN 45545-2 (Smoke and Fire behaviour) to HL3.Ampetronic drivers have a CE mark for all relevant safety and EMC standards.
Loop Performance
The T14-1 will enable an Audio Frequency Induction Loop system that meets the requirements of IEC 60118-4 and relevant parts of IEC TR 63079. To fully meet the requirements of these Standards, correct design, installation, commissioning and maintenance are required.Standards compliance to IEC 62489-1
All information specified on this datasheet has been compiled in accordance with the IEC 62489-1 Standard and reflects actual performance in realistic applications.
Technical specifications
INPUTS
| Power Options
T14-1LW, T14-1LH
T14-1UW, T14-1UH
| Nominal voltage 24-36V DC Voltage range 16.8 – 45V DC Isolation 1500V DC Recommended overcurrent protectionType C DC MCB 16A Inrush Current (max peak) 24V: 17.7 A, 36V: 18.9 A Final fault protection Non-replaceable fuse, T 25A Power Consumption Typical audio 24V: 59W (2.47A) / 36V: 61W (1.7A) Quiescent 24V: 10.3W (0.43A) / 36V: 12.6W (0.35A) Peak* 24V: 252W (10.5A) / 36V: 248W (6.9A) Nominal voltage 72-110V DC Voltage range 50.4 – 137.5V DC Isolation 1500V DC Recommended Overcurrent protection Type C DC MCB 72V: 5A, 110V: 4A Inrush Current (max peak) 72V: 7.0 A, 110V: 9.3 A Final fault protection Non-replaceable fuse, T 10A Power Consumption Typical audio 72V: 57W (0.79A) / 110V: 61W (0.55A) Quiescent 72V: 10.8W (0.15A) / 110V: 15.4W (0.14A) Peak* 72V: 233W (3.23A) / 110V: 233W (2.12A) |
| Power Connectors | Harting Han Q 3D 5-way insert (2/3 pins used) or WAGO 769 series detachable 3-way block |
| Input 1 & 2 | Pin selectable 3V/30V/100V balanced isolated line for each input |
| Sensitivity | 3V -15dBu / 30V +3.85dBu / 100V +14.8dBu |
| Input Enables | Isolated control input per channel |
| Input and Control connectors | Audio inputs, status and enables through Harting Han Q 3D 21-way or WAGO 769 series detachable blocks |
| Ethernet control I/O | HTML and Telnet control interface M12 circular Industrial Ethernet (TCP/IP), 10/100M |
| VOIP Input (option) | SIP/RTP network audio input available through ethernet connection |
OUTPUTS
| Priority Input | Option for input 2 to override other inputs with configurable attenuation level |
| Low Cut Filter | Switchable 250Hz low cut filter available on all inputs |
| Loop Output | 14ARMS (19.8Apk) up to 60 seconds continuous 1kHz |
| Drive Current | Sine wave, peak >21A Cont. pink noise >6.6ARMS |
| Drive Voltage | >24VRMS (33Vpk) available at maximum output current |
| Loop Connector | Harting Han Q 3D 2-pin (of 5-way insert) or WAGO 769 series detachable 2-way block |
| Rated THD | <0.4% (with 1kHz Sine, rated output current & load, 6dB AGC) |
| Output Impedance | >39Ω |
| Rated Load | 0.8 Ohm + 120µH |
| Status Output | Isolated relay contact and network options (inc. SNMP) Monitoring of loop resistance and operating status |
AUDIO SPECIFICATION
| Freq. Response | 65Hz to 7kHz ±3.0dB / 100Hz to 6.5kHz ±0.5dB relative to 1kHz at low level. |
| Compression | The AGC is optimised for speech. Dynamic range >36dB |
| Metal Loss Correction | Dual slope configurable MLC up to 4dB per octave |
| Phase Shift | Isolated relay contact and network options (inc. SNMP) Monitoring of loop resistance and operating status |
PHYSICAL
| Dimensions | Width 296mm, depth 217mm, height 53mm excluding connectors |
| Weight | 1.5 kg ± 0.2 kg |
| Operating temperature | According to EN50155 to OT4 -40C to +70C (+85C for 10 mins at startup) |
| Construction | Clear passivated Aluminium |
| Protection rating | WAGO IP40 Circular IP41 Harting IP42 |